Add the vent filters

Filter every gas path with five 25 mm, 0.2 μm hydrophobic A 0.2 µm hydrophobic membrane on luer fittings. Gas passes; microbes and liquid do not, so each gas path stays sterile., the ones the AEP0.2 uses. This turns a Mixed-culture electroPioreactor into a budget aseptic one.

  1. Fit one to the media bottle cap’s vent port.
  2. Fit one to the product bottle cap’s vent port.
  3. Take the CO₂ tube’s A standard medical screw fitting. A male luer (the spigot) screws into a female luer (the socket). In this build, male ends mark outlets. off the vial cap’s CO₂ inlet, fit the male end of a filter to the inlet, and connect the tube’s luer to the filter.
  4. Fit the female end of a filter to each of the vial cap’s two gas outlet luers.

Parts

  • 5×0.2 µm hydrophobic vent filterspart
  • 2×GL45 capsearlier step
  • 1×O-ring vial capearlier step

Check your work

  1. Where are A 0.2 µm hydrophobic membrane on luer fittings. Gas passes; microbes and liquid do not, so each gas path stays sterile. fitted now?

    Show the answer

    Answer: Both bottle cap vents, the CO₂ inlet and both gas outlets

    • If you see Both bottle cap vents, the CO₂ inlet and one gas outlet: Fit the female end of a filter to the other gas outlet A standard medical screw fitting. A male luer (the spigot) screws into a female luer (the socket). In this build, male ends mark outlets. too. If a luer will not take the filter: each filter has a female inlet and a male outlet, so where two female luers would meet, add a male-to-male luer lock adapter.
    • If you see The CO₂ inlet and both gas outlets, no bottle cap vents: Fit one to each bottle cap's vent port too.